Skip to main content
CalcSummitCalcSummit
Guide · Project · Stair Stringer Count

How Many Stair Stringers Do I Need?

Stringers needed equal the stair width divided by the maximum spacing, rounded up, plus 1. At 16 in on center, a 36 in wide stair needs 4 stringers and a 48 in wide stair needs 4. Thin or composite treads need closer spacing, so check the tread maker's limit first.

Need rise, run and stringer length instead? Use the stair calculator.

  • Updated November 2026
  • Sources Cited
  • No Login Required
  • Free to Use

What Sets the Stair Stringer Count

Three inputs set the count: the stair width, the tread material and the spacing limit that goes with it. A tread is a short beam that rests on the stringers. The wider the gap between stringers, the more the tread flexes. The spacing limit keeps that flex small. The count always includes both outer stringers.

  • Stair width: the finished width of the treads.
  • Tread material: 2x lumber, thin 5/4 boards or composite.
  • Spacing limit: the most on center distance the tread allows.

This guide counts stringers. For rise, run, stringer length and the bottom cut, see how to figure out stair stringers. For a full stair layout, use the stair calculator. Building a deck stair? Start with the deck building guide.

The Stringer Count Formula, Step by Step

Follow these five steps for any stair width.

  1. Measure the stair width. Use the finished width of the treads, edge to edge. A 36 in stair is the example in this guide.
  2. Find the maximum spacing for your treads. Use 16 in on center for 2x lumber treads. For composite or thin 5/4 treads, use the tread maker's limit. Most pages in the SERP show 10 to 12 in.
  3. Divide and round up. 36 / 16 = 2.25. Round up to 3 spans. Never round down, because that leaves one span wider than the limit.
  4. Add 1. 3 spans need 3 + 1 = 4 stringers. Spans sit between stringers, so there is always one more stringer than spans.
  5. Check the actual spacing. 36 / 3 = 12 in on center. That is under the 16 in limit, so the count works.
Note
Formula. Stringers = ceil(width / max spacing) + 1. Actual spacing = width / spans.
Plan view of a 36 in stair: 3 stringers leave two 18 in spans, over the 16 in limit. 4 stringers leave three 12 in spans.
Figure A. A 36 in stair with 3 stringers has two 18 in spans. With 4 stringers it has three 12 in spans.

Stringer Count by Stair Width

Find the stair width in the first column, then read the count under the spacing that fits your treads. The number in brackets is the actual spacing when the stringers are spread evenly. Every row stays at or under its limit.

Stringers needed for stair widths from 24 in to 72 in at 16, 12 and 10 in on center, with the actual spacing in brackets.
Stair width16 in limit12 in limit10 in limit
24 in3 (12 in)3 (12 in)4 (8 in)
30 in3 (15 in)4 (10 in)4 (10 in)
36 in4 (12 in)4 (12 in)5 (9 in)
42 in4 (14 in)5 (10.5 in)6 (8.4 in)
48 in4 (16 in)5 (12 in)6 (9.6 in)
60 in5 (15 in)6 (12 in)7 (10 in)
72 in6 (14.4 in)7 (12 in)9 (9 in)
Stringers needed by stair width, 24 to 72 in, at 16, 12 and 10 in spacing. A 36 in stair needs 4, 4 and 5.
Figure B. Stringers needed from 24 in to 72 in wide at 16, 12 and 10 in on center. Computed from the formula in section 02.

Does a 36 Inch Stair Need 3 or 4 Stringers?

At 16 in on center, a 36 in stair needs 4 stringers. Three stringers leave two 18 in spans. 18 in is over the 16 in limit that Decks.com, StairStringerCalculator.net, BuildCalc and MyStairCalculator all give for 2x lumber treads.

What four published pages say about the stringer count for a 36 in wide stair, read on November 23, 2026.
PageWhat it saysCheck
Decks.comNever more than 16 in on center. At least 4 stringers on a stair wider than 36 in.Does not state a count for exactly 36 in.
BuildCalcTable lists 3 stringers for 36 in at 16 in on center.Its step text calls an 18 in spacing too wide, then the table still shows 3.
StairStringerCalculator.netLists 3 stringers for 2x treads at 36 in, and 4 for composite and 5/4 treads.The 2x row uses an 18 in span, over its own 16 in limit.
MyStairCalculatorFormula: ceil(width / max spacing) + 1.Gives 4 for 36 in at 16 in.
Warning
What to do. Use 4 stringers for a 36 in stair unless the tread maker and your local building department both allow an 18 in span. Three stringers only work when the limit is 18 in or more.

Tread Material and Stringer Spacing

Treads carry the load between stringers, so the tread decides the spacing. The four pages read for this guide agree on 16 in for 2x lumber and disagree on thinner boards and composite. Where sources differ, use the tighter figure until the tread maker's instructions say otherwise.

Spacing limits found on four published pages for 2x lumber, 5/4 decking and composite treads.
TreadSpacing foundPages
2x lumber, 1.5 in16 in on centerDecks.com, StairStringerCalculator.net, BuildCalc, MyStairCalculator
5/4 decking, about 1 in12 in on center. 10 in for lower-grade boards. BuildCalc lists 16 in.StairStringerCalculator.net, Decks.com, BuildCalc
Composite and PVC10 to 12 in on center on most pages. BuildCalc lists 16 in for one Trex line when the stringers run square to the joists.BuildCalc, StairStringerCalculator.net, Decks.com

No IRC or AWC DCA 6 section on stringer spacing was found on these pages, and this guide does not cite one. Ask your building department which rule applies to your stair.

Worked Examples

Composite treads, 42 in wide

Note
Composite. A stair is 42 in wide with composite treads limited to 12 in. 42 / 12 = 3.5. Round up to 4 spans. 4 + 1 = 5 stringers. The actual spacing is 42 / 4 = 10.5 in.

2x treads, 60 in wide

Note
2x lumber. A stair is 60 in wide with 2x treads. 60 / 16 = 3.75. Round up to 4 spans. 4 + 1 = 5 stringers. The actual spacing is 15 in.

A width that divides evenly

Note
Exact. A stair is 48 in wide with 2x treads. 48 / 16 = 3 exactly, so there is nothing to round. 3 spans give 4 stringers at 16 in on center.

To lay out the cuts after you have the count, see how to figure out stair stringers. To plan the whole stair, open the stair calculator.

Common Mistakes When Counting Stringers

  • Counting spans, not stringers. 36 / 16 rounds up to 3, but 3 spans need 4 stringers.
  • Rounding down. 36 / 16 = 2.25. Rounding to 2 spans gives 3 stringers and two 18 in spans, over the limit.
  • Using one limit for every tread. 2x lumber, thin 5/4 boards and composite have different limits.
  • Skipping the tread maker's sheet. Composite makers publish their own spacing, and it can be tighter than 16 in.
  • Mixing this count with length math. Rise, run and stringer length belong to a different step.

Frequently Asked Questions

Advertisement

Sources and Review

Note
How the numbers were checked. The count table, the examples and Figure B come from one formula in code: spans = ceil(width / spacing), stringers = spans + 1. The test file covers the table, the exact-division case and the error cases.

Sources

Published November 2026. Last updated November 2026. Next review May 2027. Technical review is pending. These are third-party pages, not code text. This page is not a structural design or a permit document. For a stair that carries people, confirm the count and the spacing with the tread maker and your local building department.

Alex Rivera, PE, PE — CalcSummit expert reviewer

Reviews: volume calculators · 38 calculators reviewed